Send Message
Home News

company news about How to deal with the problem that the feeding bin of the Electronic Counting Machine is affected by the gravity of the material?

Certification
China Hangzhou SED Pharmaceutical Machinery Co.,Ltd. certification
China Hangzhou SED Pharmaceutical Machinery Co.,Ltd. certification
Customer Reviews
 I would like to thank you for all your efforts to choose the correct atomizer for our spray dryer,High speed drying. The surface area of Raw Material liquid increased a lot after atomization through nebulizer, 95%-98% of moisture will be evaporated in high temperature airflow in a flash, only needs seconds time.

—— Fatih BÜYÜKEGEN

I really don't know how to thank you, you are my angel, Thank you very much. Super Fine Pulverizing this one is faster than other same power machine and is easy to operate and repaired.

——  Hamid Doroudian 

I'm Online Chat Now
Company News
How to deal with the problem that the feeding bin of the Electronic Counting Machine is affected by the gravity of the material?
Latest company news about How to deal with the problem that the feeding bin of the Electronic Counting Machine is affected by the gravity of the material?

In view of the problem that the feeding silo of the electronic granulator is affected by the gravity of the material, it can be considered that the silo can be divided into a constant weight silo and a non-constant weight silo. In this way, the effect of material gravity on the separation of materials in the oscillating plate can be effectively dealt with.

 

Regarding the problem that it takes too long for the material to fall from the recall baffle to the bottle, it should be considered to add another level of recall baffle, which can deal with the following problems. T

 

o be able to divide the material from the recall baffle to the time of the bottle, the filling time of the bottle is shortened, and the recall baffle is closed when the bottle is loaded.

 

The counter works continuously, so that two actions can be completed, the unloading and bottling of the previous bottle and the counting of the next bottle, and the production speed is improved. Secondly, it can deal with the problem of electrostatic adsorption materials.

 

latest company news about How to deal with the problem that the feeding bin of the Electronic Counting Machine is affected by the gravity of the material?  0

 

The counting machine is mainly used for small batch quantitative packaging of capsules and tablets, and is very suitable for small and medium batch testing and production in pharmaceutical factories, scientific research institutions and laboratories. Applicable to items of different scales, able to distinguish fragments from fragments.

 

At the same time, materials can be taken out in small piles to avoid wasting production capacity. No need to split into single row lanes or separate. The single-layer oscillating disc feeding and integrated channel greatly improve the feeding density and production capacity, without the need for high-speed gates, avoiding the risk of tableting at the gate, no requirement for the cleanliness of compressed air, and compact size.

 

Now, although the application range of the particle counting machine is very wide, many people do not know how to operate it correctly, and many details of the operation process are unclear. Its correct operation is divided into pre-operation, post-operation and post-operation.

 

Before operation, the user should check whether the glass carousel and the oscillator are suspended; check whether there are other debris on the glass carousel and the discharge chute; adjust the particle opening size, adjust the tracker; adjust the height of the riser to determine the positioner.

 

After that, turn on the power and set the quantity parameters required for the production process. Watch for the turntable and shaker to start slowly and check that the particles slide smoothly. If all requirements are met, it will work.

 

During operation, the emission of oscillating particles should match the speed of the rotating disk during operation, and care should be taken that no material accumulates on the disk surface, so as not to block the track. If there is too much material, it can easily overlap or jam in the tracker and the counts will be inaccurate. The control signal of the self-stop circuit is preset and closed through the switch diode and the relay, the counting input is blocked, the counting input is grounded, and the feeding and counting are stopped.

 

In addition, the user should pay attention to the operation of the granulator, otherwise it may not work properly; when lifting the machine, do not hang the machine on the counter board, otherwise it will cause the counter board to loosen and damage; the snap ring on the counter must be adjusted to a suitable the height of. The bottom edge should be at an appropriate distance from the particle head.

 

Too low or too high will damage the pellets. The material particles must be thoroughly determined and uniform in length, and there must be no unqualified particles, otherwise the quantity and quality of the particles will be affected.

 

Buying a high-quality counting machine is the basic condition for users to ensure the quality of counting. However, in the process of use, due to improper operation or mistakes, some users will use it directly, or pay no attention to the details during the operation process.

 

The counting equipment must be operated correctly, and some details must be paid attention to in the operation process in order to achieve an excellent counting effect and ensure high-quality production.

 

Application of counting machine

latest company news about How to deal with the problem that the feeding bin of the Electronic Counting Machine is affected by the gravity of the material?  1

 

Pub Time : 2022-04-24 16:20:48 >> News list
Contact Details
Hangzhou SED Pharmaceutical Machinery Co.,Ltd.

Contact Person: Ms. Wei

Tel: 86-15372434551

Fax: 86-571-88615836

Send your inquiry directly to us (0 / 3000)