Product Details:
|
Name: | SED-250P Working Pressure 0.22Mpa Horizontal Pharmaceutical Machinery Equipment Portable Autoclave Sterilizer Hospital | Working Pressure: | 0.22Mpa |
---|---|---|---|
Adjustment Of Temperature: | 40-134℃ | Time For Sterilization: | 0-60min |
Time For Drying: | 0-60min | Heat Average: | ≤±2℃ |
Material: | Stainless Steel | Key Word: | Horizontal Autoclave |
High Light: | machinery for pharmaceutical industry,equipment for pharmaceutical manufacturing |
SED-250P Working Pressure 0.22Mpa Horizontal Pharmaceutical Machinery Equipment Portable Autoclave Sterilizer Hospital
Product Overview of Horizontal Autoclave
The horizontal autoclave,which adopted the way of gravity exchange to releasing the cold air from the chamber more completely to ensure the reliable sterilization.The control system automatically adjust the steam inlet and outlet according to chamber temperature during sterilizing.
This unit is ideal equipment for clinics,scientific research institutes and other organizations to sterilizer surgical instruments,fabricglassed,culture media etc.
Product Parameters of Horizontal Autoclave
Technical/ Model |
WS-150YDA | WS-200YDA | WS-280YDA | WS-400YDA | WS-500YDA |
chamber volume | 150L (440*1000)MM |
200L (515*1000)MM |
280L (600*1000)MM |
400L (700*1100)MM |
500L (700*1300)MM |
working pressure | 0.22Mpa | ||||
working temperature | 134℃ | ||||
adjustment of temperature | 40-134℃ | ||||
time for sterilization | 0-60min | ||||
time for drying | 0-60min | ||||
heat average | ≤±2℃ | ||||
power | 9kw | 9kw | 12kw | 18kw | 18kw |
dimension | 1400*600*1300 | 1400*670*1650 | 1400*770*1780 | 1430*880*1830 | 1800*900*1820 |
transport dimenison | 1550*750*1850 | 1560*820*1850 | 1680*920*2100 | 1600*1050*2100 | 1850*1050*2100 |
G.W/N.W | 320/240kg | 350/260kg | 465/365kg | 530/420kg | 580/470kg |
Feature of Horizontal Autoclave
▶1.Sterilizing course automatic sterilization controlled,easy to operate.
▶2.With drying function,suitable dressing drying.
▶3.With over-temperature,over-pressure auto-protect device.
▶4.The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
▶5.The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
▶6.The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.
▶7.The chamber of the sterilizer is made of stainless steel.
▶8.Time range:0-60 min.
▶9.It is with tray in the chamber.
▶10.It could make the power 220V/110V for 150L,200Lmachine.Over 280L,the power supply is 380V.
Show of Horizontal Autoclave
Application of Horizontal Autoclave
It is applicable for the sterilization of unpacked solid instrument in department of stomatology, ophthalmology,operation room and CSSD.
Contact Person: Wei
Tel: 86-15372434551
Fax: 86-571-88615836