When the automatic capsule filling machine has an abnormal fault, it may lead to the "timing" error of the cam (that is, the action sequence of each cam is wrong). During adjustment, ensure that the mechanism does not have motion interference.
The motor produces intermittent movement through the indexing box of the rotary table station through the reduction continuous operation. When it is necessary to adjust the "timing" of the cam (i.e. the cam action sequence), the handle should be used to rotate the main motor shaft.
When the filling rotation reaches a certain position, the filling rotation stops for a period of time, and the packaging rotary table stops for a period of time, what should be done is:
*The cam used for capsule distribution on the second station shall send the capsule to the upper module port;
*The cam on the second station for separating the capsule cap and body with the vacuum separator shall rise to the lower plane of the lower module, and make the vacuum system generate enough vacuum to make the capsule flow into the module and separate the cap and body;
The cam on the sixth station used to remove the undivided capsules of the automatic capsule filling machine shall rise to remove the defective capsules;
The cam used to lock the filled capsule on the eighth station shall rise to lock the capsule;
The cam used to push the finished product out of the ninth station shall rise to push the finished product out.