1. First, detect the object detection electric eye. It may be that the object cannot be sensed, so there is no label. You need to set the value of the object detection electric eye from the beginning. Maybe the object detection electric eye is damaged, and you need to replace it;
2. Check whether the traction tissue is tightened, if not, tighten the traction tissue;
3. Check whether the traction motor of the labeler/corner labeler is loose, broken or not working now;
4. The transmission synchronous belt is cracked and can be replaced;
5. It is possible that the return magnetic switch of the overlaid cylinder does not detect any signal, so adjust the orientation of the magnetic switch from the beginning or change it;
6. If the non marking switch is pressed, it shall be disconnected;
7. Check whether the traction is turned over. Only when the label is turned over can you walk around and label out. The speed value is set to 0;
8. Or it is the problem of the label itself. The label is too thin and irregular to peel off;
9. The label stripping plate of the labeling machine/side labeling machine shall not be sharp, and the label cannot be peeled off.